M05 - HOUR COUNTER
P05.01
Hour meter counter enable
P05.02
Partial hour counter enable
P05.03
Channel number (x)
P05.01 – If set to OFF the hour meter s are disabled and the hour meter page is not shown.
P05.02 – If set to OFF, the partial hour meter is not incremented. If ON, time is incremented as long as DMG is powered.
P05.03 – Number of the channel (x) of the variable eventually used in the previous parameter. Example: If the partial hour counter must count the time during
which one measurement is above a certain threshold, e.g. defined by LIM3, then it is necessary to program LIM in the previous parameter and channel 3 in this
parameter.
M06 - TREND GR PH
P06.01
Trend graph measurement
P06.02
utorange
P06.03
Full scale value
P06.04
Full scale multiplier
P06.01 – Selects the reading to be shown on trend graph page.
P06.02 – Choice between automatic range or fixed range defined by the user.
P06.03 – Full scale range value. The unit of measure is the one defined by the selected reading.
P06.04 – Full scale value multiplier.
M07 - COMMUNIC TION
P07.n.01 Serial node address
P07.n.02 Serial speed
P07.n.03 Data format
P07.n.04 Stop bits
P07.n.05 Protocol
P07.n.06 IP ddress
P07.n.07 Subnet mask
P07.n.08 IP port
P07.n.09 Gateway function
P07.n.10 Client / server
P07.n.11 Remote IP address
P07.n.12 Remote IP port
P07.n.13 IP gateway address
Note: this menu is divided into 2 sections, for comm channels COM1..2
P07.n.01 – Serial address (node number) for the communication protocol.
P07.n.02 – Serial communication speed.
P07.n.03 – Data format. Can be set to 7 bits only for SCII protocol.
P07.n.04 – Number of stop bits.
P07.n.05 – Communication protocol selection.
P07.n.06, P07.n.07, P07.n.08, P07.n.13 –TCP-IP coordinates for application with Ethernet interface. Not used for other types of interface modules.
P07.n.09 – Enables the gatreway function. See details in Communication channels chapter.
P07.n.10 – Enabling TCP-IP connection. Server = waits connection from a remote client. Client = Establishes a connection to the remote server.
P07.n.11, P07.n.12 – Coordinates for the connection to the remote server when P07.n.10 is set to Client.
UdM
Default
Range
ON
OFF-ON
ON
OFF-ON- INPx-
LIMx-BOOx
1
UdM
Default
Range
kW (tot)
VL-L (eq) VG
VG
kW (tot) VG
kvar (tot) VG
kV (tot) VG
ON
OFF-ON
1000
0-1000
x1
x1 - x1k - x1M
UdM
Default
Range
01
01-255
bps
9600
19200
38400
57600
115200
8 bit - n
8 bit, no parity
8bit, odd
8 bit, even
7 bit, odd
7 bit, even
1
Modbus RTU
Modbus RTU
Modbus SCII
Modbus TCP
000.000.000.000
000.000.000.000 -
255.255.255.255
000.000.000.000
000.000.000.000 -
255.255.255.255
1001
0-9999
OFF
OFF/ON
Server
Client / Server
000.000.000.000
000.000.000.000 –
255.255.255.255
1001
0-9999
000.000.000.000
000.000.000.000 –
255.255.255.255
G
1-8
B
1200
2400
4800
9600
1-2