Table Of Parameters - LOVATO ELECTRIC DMG800 Manuel D'application

Masquer les pouces Voir aussi pour DMG800:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

P R METER T BLE
M01 - GENER L
P01.01
CT primary
P01.02
CT secondary
P01.03
Rated voltage
P01.04
VT usage
P01.05
VT primary
P01.06
VT secondary
P01.07
Type of wiring
P01.01 - CT primary winding rated current.
P01.02 – CT secondary winding rated current.
P01.03 – System rated voltage. Leaving to ut the multimeters automatically adapts bar-graph full scale.
P01.04 – Set to ON if VT are used. If set to OFF, the following two parameters will be ignored.
P01.05 – VT primary winding rated voltage.
P01.06 – VT secondary winding rated voltage.
P01.07 – Set this parameter according to the used wiring diagram. See witring diagrams on last pages of the manual.
M02 - UTILITY
P02.01
Language
P02.02
Display contrast
P02.03
High backlight level
P02.04
Low backlight level
P02.05
Low backlight delay
P02.06
Default page return
P02.07
Default page
P02.08
Default sub-page
P02.09
Display update time
P02.06 – If set to OFF the display always remains in the page where the user left it. If set to a time delay, after that time the display page goes back to page set
in P02.07.
P02.07 – Number of the page to which the display returns automatically after time specified by P02.06 has elapsed from the last keystroke.
P02.08 – Sub-page type to which the display returns after P02.06 has elapsed.
M03 - P SSWORD
P03.01
Enable passwords
P03.02
User level password
P03.03
dvanced level password
P03.01 – If set to OFF, password management is disabled and the access to setup parameters and command menu is allowed.
P03.02 – When P.03.01 enabled, value to be specified to get user access.
P03.03 – Like P03.02, but referred to advanced access.
M04 - INTEGR TION
P04.01
Integration mode
P04.02
Power integration time
P04.03
Current integration time
P04.04
Voltage integration time
P04.05
Frequency integration time
P04.01 – Selection of average reading calculation method:
Fixed = Readings are integrated for the set time. Every time the integration time elapses, the verage value is updated with the result of the last integration.
Shift = The instantaneous values are integrated for a period f time equal to 1/15th of the set time. Every time this interval elapses, the oldest value is replaced
with the new one just calculated. The average value is updated every 1/15th of the time set, considering a time-sliding window that groups the last 15 calculated
values, with a total length equal to integration time setting.
Sync = Like fixed mode, but the integration intervals are started by an external digital input programmed with Synchronization function.
Bus = Like fixed mode, but the integration intervals are started by communication messages on the serial bus.
P04.02 – verage readings integration time, used for active, reactive and apparent power.
P04.03, P04.04, P04.05 – Readings integration time ( VG) for the correspondent measurements.
UdM
Default
Range
5
1-10000
5
V
ut
ut / 50-500000
OFF
OFF-ON
V
100
50-500000
V
100
50-500
L1-L2-L3-N
L1-L2-L3-N
L1-L2-L3
L1-L2-L3-N BIL
L1-L2-L3 BIL
L1-N-L2
UdM
Default
Range
English
English
Italiano
Francais
Espanol
Portoguese
%
50
0-100
%
100
0-100
%
30
sec
30
5-600
sec
60
OFF / 10-600
VL-L
VL-L / VL-N ...
INST
INST / HI / LO /
VG / MD /GR PH /
sec
0.5
0.1 - 5.0
UdM
Default
Range
OFF
OFF-ON
1000
0-9999
2000
0-9999
UdM
Default
Range
Shift
Fixed / Shift
Sync. / Bus
min
15
min
15
min
1
min
1
1/5
G
B
L1-N
0-50
1-8
1-60
1-60
1-60
1-60
11

Publicité

Table des Matières
loading

Table des Matières