SI 130TUR+
6
Electrical connection
6.1
Load voltage / Fuse protection
6.2
Control voltage / Fuse protection
6.3
Nominal power consumption
6.4
Starting current with soft starter
3
6.5
Nominal current
6.6
Max. power consumption of compressor protection
(per compressor)
7
Complies with the European safety regulations
8
Additional model features
8.1
Water in device is protected against freezing
8.2
Hydraulic 4-way reversing valve (external
8.3
Max. operating overpressure (heat source/heat sink)
1. see output curves / for brine inlet temperatures from -5°C to +5°C, flow temperature rising from 50°C to 58°C.
2. Operation with 1 compressors
3. Operation with 2 compressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and oper-
ation can be found in the respective sections of the installation and operating instructions. The specified values, e.g. B0 / W55, have the following meaning: Heat source tem-
perature 0 °C and heating water flow temperature 55 °C
5. Domestic hot water preparation via additional heat exchanger in parallel operation: The waste heat output is dependent on the current operating point. The waste heat output
falls when the cyclinder temperature rises.
6. The coefficients of performance for parallel domestic hot water preparation are also achieved via additional heat exchangers.
7. The values specified apply when using the hydraulic 4-way reversing valve, available as an option (observe instructions for accessories). The heat outputs are reduced by ap-
proximately 8%, and the COPs by approximately 10%, when the 4-way reversing valve is not used.
8. Necessary for ensuring waste heat recovery in cooling operation.
9. Considerably higher COPs are achieved with cooling operation and waste heat recovery using additional heat exchangers.
10.The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C. The specified sound pressure
level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
11.Note that additional space is required for pipe connections, operation and maintenance.
12.Using the reducing nipple supplied.
13.Double nipples matching the connection sized are included in the scope of supply.
14.See CE declaration of conformity
15.The heat circulating pump and the heat pump manager must always be ready for operation.
www.gdts.one
4 3
B0 W35
kW
A
B0 W35 / cos 
A / ---
W
15
7
bar
.
452234.66.75 · FD 9912
3-/PE 400 V (50 Hz) / C80A
1-/N/PE 230V (50Hz) / C13A
25.83
108
46.6 / 0.8
120; thermostatically controlled
14
yes
Accessories (recommended)
3.0
English
EN-13