ADVICE DURING INSTALLATION AND ASSEMBLY OPERATIONS.
During the connection operations of the electrical wiring to the filter modules, great attention must be
given to polarity, and it must be verifi ed that pieces of wiring are not left inside after closing.
Make all connections by following the instructions in this manual.
It should be verified that the electrical wiring connections to the electronic card are fi rmly made.
The seal on the module's box should be checked for correct positioning to prevent the entry of water, it
should also be checked that the compression gland is also correctly located.
Particular attention should be paid, so that, under no circumstances, is it possible for water to enter
the electronic module. In the case where the intended use is not that for which the valve was designed,
adaptation and supplementary technical regulations may be necessary.
ADVICE FOR WHEN PUTTING INTO SERVICE.
Before putting the filter into service, it is necessary to verify the calibration of the electrical protection
devices in the operations cabinet and that they are correctly positioned and fi xed in place.
The maximum voltage values must never be exceeded under any circumstances.
In the case of incorrect operation or a fault, please contact the closest manufacturer's representative
or technical assistance service.
NOTE: It is recommended that the bathing facilities are not used while the fi ltration
equipment is in operation.
ADVICE DURING INSTALLATION AND MAINTENANCE WORK.
National installation regulations must be taken into account when assembling and installing the filter.
Extra care must be taken so that it is not possible, under any circumstances, for water to enter the filter
electronic circuit.
All contact, including accidental, must be avoided at all times with the moving parts in the filter during
operation and/or before complete shutdown.
Before carrying out any maintenance or any other electrical or electronic work, it must be ensured that
switch-on devices are locked.
It is recommended that the following steps be taken before performing any maintenance on the filter:
1- Remove electrical power to the filter.
2- Lock the switch-on devices.
3- Verify that there is no electrical power being applied to the circuits, including auxiliary and
supplementary services.
This list must be considered indicative and not binding with respect to safety, there may
be other specifi c safety standards in particular regulations.
IMPORTANT: due to the complexity of the situations covered, the instructions for installation, use
and maintenance contained in this manual, do not make any attempt to cover all possible service and
maintenance cases. If additional instructions are necessary or specifi c problems arise, please do not
hesitate in contacting the distributor or the filter manufacturer directly.
Our filters may only be installed in swimming or other pools which fully comply with the HD 384.7.702
standard. When any doubt exists a specialist should be consulted.
1. CONTENT OF 67355-67356-67357:
Inside the box, you will find:
- Nanofiber filter
- Nanofiber filter cartridge (inside the filter)
- Bag of components:
Pressure gauge
Connections
Additional cable gland
Operating Instructions
2. CONTENT OF 67509 KIT:
If you have purchased the 67509 KIT you must
begin the installation in step nº7. Inside the box,
you will find:
- Cover assembly
- Bag of components:
Pressure gauge
Additional cable gland
Operating Instructions