4.- Glue the sleeve (code 65289)
that comes with the NanoFiber filter
to the 2" connection at the bottom
of the valve.
5.- Perform the three connections of
the selector valve: pump piping to
the valve, valve to the waste drain
and valve to the pool return. Each
of these three outlets is clearly
identified on the valve.
6.- Set the manometer T, the joint, the manometer and
the air drainage (see exploded view). It is not necessary
to use teflon tape, as the watertightness is guaranteed in
this case by the joint. Do not tighten the manometer T
with a tool, as manually will be sufficient.
6. POSITION OF THE CARTRIDGE:
The cartridge comes properly fitted from the factory.
If you wish to remove the filter in the future, follow the steps
described below:
1. Stop the filtration pump and set the valve to the Off
position.
2. Open the drainage cap and release the air.
3. Unscrew and remove the cover assembly.
4. Remove the cartridge.
5. Put a new cartridge in place, check that it is well secu-
red and that it can be turned with your hand.
6. Put the seal in place and check that it is firmly in
position.
7. Screw the cover assembly back in.
8. Set the valve to the Filtration position.
9. Close the drainage cap until there is no longer any air inside the filter.
Warning: when the filter is running check that no water leaks from the lid.
Note: the manufacturer takes no responsibility for any damage to the filter when the cartridge is being
changed.
- Gluing sleeve 65289 -
- Assembly of the manometer -
5
Automatic