CaLIBRaTION MOdES
This tester includes two different Calibration Modes. Please read
the description below to determine which calibration mode you
wish to use.
1. Simple Calibration Mode: In Simple Calibration Mode if you apply
an offset to a given grain the tester will simply apply that offset to the
displayed moisture regardless of the moisture content or range. This
means there is just a single offset that will be applied to the grain.
The calibration offset can also be adjusted at any time without having
to take a valid test. This is the default mode for the tester. Example:
You have tested two grain samples, one at 10%, and the other at
20%. You have retested the 20% grain and apply a 2% offset. If you
now retest the two samples the new results are as follows:
Original
20%
10%
2. advanced Calibration Mode: In Advanced Calibration Mode
you must first take a valid test before you can adjust the offset for
the tested grain. Once a test is taken and the offset is made, the
adjustment will only be applied to the moisture range of the grain just
tested. So if you are making large adjustments at higher moisture
levels, the offset that you apply will not affect the lower moisture of
the same grain. This means that multiple tests can be taken for a
grain at different moisture ranges and different offset can be applied
to each of the ranges. Example: You have tested two grain samples,
one at 10%, and the other at 20%. You have retested the 20% grain
and apply a 2% offset. If you now retest the two samples the new
results are as follows:
Original
20%
10%
NOTE: Regardless of the mode selected (Simple or Advanced) each
grain can still be individually adjusted.
Operation
Moisture display with user offset applied
22%
12%
Moisture display with user offset applied
22%
10%
05-7