EnErgy 4 SPEED
during charging. The cooling of batteries is made by a fan. The fan runs once a cell will be charged and turns off when
all inserted cells have been fully charged. Then the charger switches automatically to trickle charging.
lED inDiCatOrS
> Green LED flashes slowly (1 time per sec.) „charge": battery is being charged
> Green LED flashes quickly (4 times per sec.) „error": no charging; battery defective or non-rechargeable
battery recognised
> Green LED lights continuously „ready": battery fully charged; after termination of fast charging the unit
switches over to trickle charging; the cells may be left in the charger until they are needed without being
overcharged or losing capacity
EnVirOnMEntal COMMEntS
Do not dispose the device in the normal household waste. Please return it to your dealer or to your nearest
recycling centre or collection point. Please recycle all packing materials for the sake of the environment.
Batteries must not be disposed of in the household waste. Dispose batteries at a collection point or at an
appropriate retail store.
CarE & MaintEnanCE
To make sure that the charger works properly, please keep the contacts in the charging slots free from dust or
contamination. To clean the unit disconnect it from the mains and use only a dry cloth.
tECHniCal Data
Power supply
Input:
Output:
Charger
Input:
Max. charging current:
Mignon AA:
Micro AAA:
100 - 240V AC / 50 - 60Hz
12V DC 1.5A
12V DC 1.5A
Fast charge
Standard charge
2100mA
850mA
850mA
350mA