Télécharger Imprimer la page

Possible Faults, Causes And Solutions; Technical Data - Espa WIPER Serie Manuel D'instructions

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13

8. POSSIBLE FAULTS, CAUSES AND SOLUTIONS

1) The pump does not deliver any flow.
2)
The pump does not start.
3) The motor starts and stops automatically (klixon).
4) Insufficient flow.
5)
The Pump is noisy.
1 2 3 4 5 POSSIBLE PROBLEM
Incorrect voltage
X X
Thermal relay tripped
X
Diameter of suction line smaller than
X X
required
Lack of water in the hydromassage
X X
assembly
X Incorrect pump attachment
Lack of power
X
X
Jets or pipes clogged
X
X
Air entry trough suction line
X X
Pump seized

9. TECHNICAL DATA

Liquid temperature: ......................... 4ºC - 50ºC
Ambient temperature: ..................... 0ºC - 40ºC
Storage temperature: ................... -10ºC - 50ºC
SOLUTIONS
Verify the voltage specified on the nameplate and that of
the mains
Reset thermal relay
Correctly dimension suction line
Fill the hydromassage assembly with water
Attach the pump correctly
Reset the fuses
Clean them properly
Verify condition of connectors and gaskets of suction line
Contact qualified personnel
Ambient relative humidity, max.: ............... 95%
Motor class I.
Other data see Figure 2.