Possible Faults, Causes And Solutions; Technical Data - Espa TECNOPLUS15 4 M Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
6.
PLATE SHOWING CHARACTERISTICS

7. POSSIBLE FAULTS, CAUSES AND SOLUTIONS

1) The pump will not start.
2) The pump does not Stop.
3) The pump does not suck in.
4) Pressure or flow insufficient.
5) The motor overheats.
6) The pump starts but stops soon after (klixon)
7) The pump starts and stops continuously.
1 2 3 4 5 6
7
POSSIBLE PROBLEM
Pump blocked
X
X X
X X
Foot valve clogged
X
X X
Total manometric head higher than rated Check geometric height and head losses
Voltage incorrect
X
X X
Reduction of water level in the well
X X
Fuse or thermal relay faulty
X
Turbines worn
X
X X
Foot valve not submerged
X X
Forgot to prime the pump
X X
Poor ventilation in premises
X X
Air leaks
Wrong programming
X
The electronics section has detected lack
X
of water
X
X X
Valve or tap switched off
X
X
Lack of water
X
X
X
Loss of water through the discharge pipe Repair the leak

8. TECHNICAL DATA

Liquid temperature: ......................... 4ºC - 35ºC
Ambient temperature: ..................... 0ºC - 40ºC
Storage temperature: ................... -10ºC - 50ºC
DESCRIPTION
1
Item reference
2
Voltage + frequency + item specifications
3
Flow
4
Pressure
5
Nominal voltage, no. stages, alternate current symbol and frequency
6
Capacitor (Single-phase model)
7
EC mark + year of manufacture
8
Humidity protection level
9
Minimum working pressure
10
Maximum pressure
11
Pump serial no. (Fig.4)
12
Max. liquid temperature
13
Electric pump unit absorbed power(P1)
14
Designated motor insulation
15
Continuous operation symbol
16
Maximum nominal intensity at nominal voltage
17
Name and address of vendor responsible for the product
SOLUTIONS
Remove it and take it to an Official Technical
Service centre
Clean or replace with new one
Check that the voltage is the same as that shown
on the specifications plate
Adjust the suction height
Replace fuse or thermal relay
Remove the pump and go to an Official Technical
Service centre
Submerge the suction pipe properly
Fill the pump body with water
Ensure good ventilation
Ensure that connectors and seals are leaktight
Check programming
Find the reason for the loss of water
Open the valve or tap
Wait till the level is restored and press reset
Ambient relative humidity, max.: ............... 95%
Motor class I.
Other data see Figure 2.
12
EN

Publicité

Table des Matières
loading

Table des Matières