ELECTRIC FRYERS
THE APPLIANCE DOES NOT HEAT.
Possible causes:
-
Temperature thermostat defective.
-
Heating elements defective.
HEATING CANNOT BE ADJUSTED.
Possible causes:
-
Temperature thermostat defective.
18. REPLACING COMPONENTS
REMINDERS FOR REPLACING COMPONENTS
SHUT THE GAS SHUT-OFF VALVE
AND/OR SWITCH THE APPLIANCE OFF
AT THE MAIN SWITCH INSTALLED
UPSTREAM.
AFTER REPLACING A GAS SYSTEM
COMPONENT, CHECK FOR GAS LEAKS
AT CONNECTION POINTS.
DISCONNECT THE APPLIANCE ELECTRIC
SUPPLY, IF PRESENT, BEFORE CARRYING
OUT ANY OPERATION.
AFTER REPLACING AN ELECTRICAL
SYSTEM COMPONENT, CHECK IT IS
CORRECTLY WIRED.
GAS FRYERS
REPLACING
THE
GAS VALVE
THERMOSTAT.
- Empty the well completely.
- Open the door.
- Remove the control panel.
- Remove the bulb from its seat on the well.
- Remove and replace the component.
- Change the sensor/bulb sealing O-Ring in the well.
- Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE NOZZLE AND THE MAIN BURNER
PRIMARY AIR REGULATION
- Slacken screw V.
- Remove nozzle UM (fitted to air regulator Z) and
- Retighten nozzle UM (fitted to air regulator Z).
- Adjust air regulator Z to distance A as shown in
- Retighten screw V fully.
- Reassemble all parts. For assembly, proceed in
- Open the door.
- Remove the control panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
- raise the heating element in vertical position
- remove the lower protecion panel
- disconnect the heating elements
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
- Remove the control panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
AND
SAFETY
- Remove the control panel.
- Remove the bulb from its seat on the well.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
26
replace it with the one indicated in table TAB1.
table TAB1.
reverse order.
REPLACING
THE
PILOT
THERMOCOUPLE.
reverse order.
ELECTRIC FRYERS
REPLACING THE HEATING ELEMENT
reverse order.
SOSTITUTION OF THE LAMP
reverse order.
REPLACING THE WORKING THERMOSTAT.
reverse order.
19. CLEANING THE INTERIOR
BURNER
AND