Reference Standards And Laws; Unpacking; Positioning; Connections - Virtus A1 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
- Installation and conversion to a different type of
gas must be carried out by qualified technicians
authorized by the manufacturer, in compliance
with current safety standards and the instructions
in this manual.
- Appliance maintenance and conversion to a
different type of gas must be carried out by
qualified technicians authorized by the
manufacturer, in compliance with current safety
standards and the instructions in this manual.
- Do not obstruct any air vents or drains present on
the appliance.
- Do not tamper with appliance components.

4. REFERENCE STANDARDS AND LAWS

- Install the appliance in accordance with the safety
standards in force in the country.

5. UNPACKING

- Check the state of the packing and in the event of
damage, ask the delivery person to inspect the
goods.
- Remove the packing.
- Remove the protective film from the outer panels.
Use a suitable solvent to remove any residual
adhesive from the panels.

6. POSITIONING

The overall dimensions of the appliance and the
position of connections are given on the
installation diagram at the end of this manual.
-
- The appliance can be installed singly or in
combination with other appliances in the same
product range.
- The appliance is not suitable for integrated
installation.
- Position the appliance at least 10 cm from
adjacent walls.
- If the appliance is to be be placed near walls,
dividers, kitchen furniture, decorative elements
etc. this must be made of non-combustible
materials
Otherwise, they must be covered with suitable
non-combustible heat insulating materials.
Level the appliance by means of the height-
adjustable feet
APPLIANCE ASSEMBLY WITH BASE AND BRIDGE
Follow the instructions provided with the type of
support utilized.
FUMES EXHAUST SYSTEM
Create a fumes exhaust system based on the "
Type " of appliance. The " Type " is stated on the
appliance dataplate.
" A1 " TYPE APPLIANCE
Position the "A1" type appliance below an
extractor hood to ensure smoke and fumes
generated by cooking are removed.
" B21 " TYPE APPLIANCE
Position the "B21" type appliance below an
extractor hood.
" B11 " TYPE APPLIANCE
Fit the "B11" type appliance with a suitable fl ue,
available from the appliance manufacturer. Follow
the assembly instructions provided with the flue.
Connect the flue to a 150/155 mm diameter hose,
heat resistant to 300°C.
Vent to the outside or into an effi cient fl ue. The
hose length must not exceed 3 metres.
VENTILATION
The romms in which gas appliances are installed
must be well ventilared in order to allo correct gas
combustion and ventilation.
The air flow necessary for combustion is at least 2
m3/h for each kW of rated power.

7. CONNECTIONS

The position and dimensions of connections are
given in the installation diagram at the end of this
manual.
CONNECTION TO THE GAS SUPPLY
- Check that the appliance is designed to operate
with the type of gas supply present on site. Check
the information given on the decals on the
packing and appliance.
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B21B11

Table des Matières