Rear Exit - Napoleon Ascent 36-1 Manuel D'installation Et D'opération

Modèles de gaz naturel et de propane
Masquer les pouces Voir aussi pour Ascent 36-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Example:
V
= 1.5 FT (0.5m)
1
V
= 5 FT (1.5m)
2
V
= V
+ V
= 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m)
T
1
2
H
= 1 FT (0.3m)
1
H
= 1 FT (0.3m)
2
H
= 10.75 FT (3.3m)
3
H
= H
+ H
+ H
= 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m)
R
1
2
3
H
= .03 (three 90° elbows + one 45° elbow - 90°)
O
= .03 (270° + 45° - 90°) = 6.75 FT (2.1m)
H
= H
+ H
= 12.75FT (3.9m) + 6.75FT (2.1m) = 19.5 FT (5.9m)
T
R
O
H
+ V
= 19.5FT (5.9m) + 6.5FT (2m) = 26 FT (7.9m)
T
T
Formula 1:
H
< 3 V
T
T
3 V
= 3FT (0.9m) x 6.5FT (2m) = 19.5FT (5.9m)
T
19.5FT (5.9m) = 19.5FT (5.9m)
Formula 2:
H
+ V
< 40 FT (12.2m)
T
T
26 FT (7.9m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
2.10

rear exit

WARNING
!
Failure to create a seal to the firebox with the exhaust collar assembly will cause the appliance to function
improperly and can cause injury or property damage.
Remove the safety barrier and glass front (see "safety barrier
A.
& door removal/installation" section).
Remove the contents from the firebox and set aside. You will
B.
need the exhaust flue collar from the top of the log carton.
To ease assembly, remove the four hex head screws
C.
securing the deflector from inside the top front of the firebox
(Fig. 1).
Place the gasket (provided) over the 4" (102mm) flue collar
D.
assembly and bend along perforation.
From inside the firebox, insert the 4" (102mm) flue collar through the
E.
back of the firebox. Install the rear exit shield onto the 4" (102mm)
flue collar (see "rear exit shield" section).
Secure the flue collar assembly, gasket and rear exit shield using
F.
the four hex head 3/8" thread cutting screws (Fig. 2).
note:
Do not overtighten. The gasket needs only to be
snug against the firebox.
Reattach the deflector using the four screws and install
G.
the log set, glass door and safety barrier.
Install the 7" (177mm) collar assembly,
H.
complete with gasket, onto the rear
panel around the 4" (102mm) collar
with the screws provided (Fig. 3).
venting requirements
90°
H
2
45°
V
1
H
1
90°
DEFLECTOR
DÉFLECTEUR
V
2
90°
H
3
18.2_3B
Fig. 1
Fig. 2
GASKET
INTAKE COLLAR
ASSEMBLY
Fig. 3
W415-2835 / A / 12.09.20
EN