Venting Requirements; Typical Vent Installation - Napoleon Ascent 36-1 Manuel D'installation Et D'opération

Modèles de gaz naturel et de propane
Masquer les pouces Voir aussi pour Ascent 36-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that
it is unobstructed and undamaged.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not
be combined.
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two
horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.
Horizontal runs may have a 0" rise per foot or 0mm rise per meter however for optimum performance it is recommended
that all horizontal runs have a minimum 1/4" rise per foot or 21mm rise per meter using fl exible venting. For safe and proper
operation of the appliance, follow the venting instructions exactly.
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings
and serves both dwellings. Local codes or regulations may require different clearances.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼" (31.8mm) air gap
all around between the inner liner and outer liner is required for safe operation.
This appliance is certified for use with a power vent kit. Contact your local authorized dealer for more information.
If approved for use with a power vent kit, state: "This appliance is certifi ed for use with a
For optimum performance, it is recommended that all horizontal runs have a minimum 1/4" rise per foot or 21mm
power vent kit. Contact your local authorized dealer for more information."
rise per meter using flexible venting.
If not, cover with a white box.
2.1

typical vent installation

8" (203mm)
minimum
REQUIRED RISE ON HORIZONTAL VENTING
DRAFT
Rigid Venting
Rear Vent
Flexible Venting
Rigid Venting
Top Vent
Flexible Venting
Rigid Venting
Rear Vent
Corner
Flexible Venting
24" (61cm)
maximum
TOP VENT

venting requirements

7.1G
0" / FT
0" / FT
0"
6" (152mm)
16" (40.6cm)
minimum
40ft (12m)
maximum
3ft (1m)
minimum
34 5/8"
(86cm)
W415-2835 / A / 12.09.20
EN
11

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

B36ntr-1B36ntre-1B36ptr-1B36ptre-1

Table des Matières