Definitions; Elbow Vent Length Values - Napoleon Ascent 36-1 Manuel D'installation Et D'opération

Modèles de gaz naturel et de propane
Masquer les pouces Voir aussi pour Ascent 36-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

venting requirements
EN
2.5

definitions

For the following symbols used in the venting calculations and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
- total of both horizontal vent lengths (Hr) and offsets (Ho) in feet
T
H
- combined horizontal vent lengths in feet
R
H
- offset factor: .03 (total degrees of offset - 90°*) in feet
O
V
- combined vertical vent lengths in feet
T
2.6

elbow vent length values

FEET
0.03
15°
0.45
30°
0.9
45°
1.35
90°*
2.7
* The fi rst 90° offset has a zero value and is shown in the formula as - 90°
16
W415-2835 / A / 12.09.20
INCHES
MILLIMETERS
0.5
12.7
6.0
152.4
11.0
279.4
16.0
406.4
32.0
812.8
14.1
15.1A

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

B36ntr-1B36ntre-1B36ptr-1B36ptre-1