Technical data:
D/W/H:
Weight:
Power supply:
Fuse:
Power uptake:
Max. amount dispensed:
Min. amount dispensed:
Water tank:
Accessories and single components:
Art.Nr.:
116160
Masterbox, complete
116125
Plaster container with lid, 5 kg
116120
Plaster container with lid, 10 kg
116130
Plaster container lid
Packing list:
No.
116160
Masterbox complete
inkl.: 3 pcs. container lid
3 pcs. Plaster container 5 kg
Water tank 5 l
Power cord
Protection cover for scales
User manual
700 x 460 x 800 mm
ca. 56 kg
110/115/230V 50/60Hz
T2A
80 W
1,000 g
50 g
Approx. 5 l
WARNINGS AND
!
SAFETY ASPECTS
The Masterbox was developed for use in dental la-
boratories. It must be installed and operated as
described in the user's manual.
The manufacturer is not liable for damage caused
by using the unit for other purposes or handling it
incorrectly.
In addition, if the intended application is not listed
in the user's manual, the user is obliged to check
personally in advance that the unit is suitable for
this purpose.
• Do not clean the Masterbox with liquids
containing solvent!
• Keep the container lid and plaster dispensing
nozzle clean and dry!
• Keep the weighing machine clean and dry!
• Only fill the container with dental plaster and
never with investment or other materials!
• For safety reasons, this unit can only be ope-
rated with the plaster container positioned
correctly. (Sliding covers positioned parallel to
the top of the unit - horizontally)
• Never grasp into the plaster dispensing nozzle
while the unit is switched on.
• Always unplug the unit when changing the
plaster container!
• Never clean the Masterbox with compressed
air!
• Always clean the feed screw fully before
transporting the Masterbox!
• Never expose the Masterbox to increased
atmospheric humidity (e.g. steam cleaner,
ultrasonic cleaner or wash basin)!
• Never run the Masterbox water pump without
water.
• Only fill the water tank with pure water, with
no added chemicals!
GB
15