SubDrive/MonoDrive

Accessing the Drive

After making a successful connection to the drive, launch the FE Connect mobile app.
The FE Connect mobile app can be downloaded from the Apple App Store or Google Play
depending on the device being used.
Set-up
The Set-up screen allows for the set-up of additional features of the drive including:
Drive Output*
Motor Size*
Pump Size*
Underload Sensitivity*
Underload Off Time
Minimum Frequency
Maximum Frequency
Bump Mode
Large Tank Mode
Aggressive Bump
Broken Pipe Detection
Steady Flow*
Units (hp or kW)
* In order to change and use settings from this page for the Drive Output, Motor Size, Pump
Size, Underload Sensitivity and Steady Flow, the FE Connect DIP switch (SW1, Position 1)
on the drive must be "ON". Otherwise, the drive will default to the Motor Size, Pump Size,
and Underload Sensitivity settings made via the DIP switches and Underload Sensitivity
rotary knob on the drive itself.
Monitoring
This screen allows for real-time monitoring of the system including:
System Status
Input Voltage
Output Voltage
Output Current
Motor Speed
System Information (Drive Model, Hardware Version, Software Version)
Logs
This screen allows the Fault History and Configuration Change History logs to be viewed
and emailed. This page screen also displays the total Drive On Time and Motor Run Time.