Suunto ADVIZOR Manuel D'instructions page 46

Masquer les pouces Voir aussi pour ADVIZOR:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 64
In the Barometer mode, PRESS the [Select] button once to enter this sub mode.
In the Pressure Difference Measurement sub mode (Fig. 46):
Field 1 displays the change in temperature.
Field 2 displays the change in atmospheric pressure.
Field 3 displays the current time, to the left of the time is the text “differ”.
The Outer Circumference graphically displays the change in pressure where one full circle equals 100
mbars or 1 inHg.
This mode does continue in the background and allows the user to move to other modes and at the user’s
convenience return to this sub mode to view the current reading.
1. PRESS the [Select] button and hold in for 2 seconds. Located in Field 1 is the text “SET”; located in Field 2,
zero will begin to flash (Fig. 47).
2. PRESS the [Mode] button to accept the flashing zero and start the difference measurement.
If the user does not desire to begin the difference measurement, PRESS either the [+] or the [-] button to toggle
to the current barometric pressure reading, then PRESS the [Mode] button to exit the setup program.
Note: If the user does not press any button for 1 minute in the setup mode, the display will automatically exit
setup.
5.2 4-DAY MEMORY SUB MODE
In the Barometer mode, PRESS the [Select] button twice to enter this sub mode. This sub mode allows the user
to follow changes in pressure over the past 4 days, making weather conditions forecasting possible.
In the 4-day memory mode (Fig. 48):
Field 1 displays the day of the week the user is in;
Field 2 displays the atmospheric pressure; and
Field 3 displays the time and to the left the text “Memory”.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Metron

Table des Matières