Connecting The Appliance - Atag KD8178AFUU/A01 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

u To align the unit door in depth: Undo top screws
Fig. 23 (35) , bottom hexagon screws Fig. 23 (13) , then
move the door.
u Do not allow the knobs and sealing lips
to abut - vital for proper function!
u Allow an air gap of 2 mm between the
unit door and the body of the unit.
For large or sectioned unit doors:
u fit a 2nd pair of mounting brackets
Fig. 10 (12) .
u Use the holes pre-drilled in the handle area
of the appliance door for this purpose.
u Check the fit of the door and adjust if necessary.
u Tighten all screws.
Fig. 24 (32) using the ring spanner
u Tighten the locknuts
Fig. 24 (38) , while holding fast the adjusting bolts
Fig. 24 (33) with a screwdriver.
u Attach
top
cover
Fig. 25 (39) and snap into
place.
u Attach
side
cover
Fig. 25 (40) , push it to the
limit and then press until it
audibly snaps into place.
Fig. 25 (41)
u Attach covers
sideways, then draw them
forwards with a screwdriver
so that they snap into place
well.
u Put on and engage the covers
Door stop cushioning can be adjusted in appliances with an
aperture height of up to 1220 mm:
Fig. 23
Fig. 24
Fig. 25
Fig. 7 (4,6,7) .

Connecting the appliance

The door stop cushioning can be
adjusted if necessary using the
accompanying Allen key 5:
u For stronger spring force: turn
clockwise.
u For lesser spring force (as-deliv-
ered): turn anticlockwise.
Check the following points to ensure the appliance is fitted
properly. Failure to do so may lead to icing, condensate
forming and malfunction:
w The door has to close properly
w The unit door must not butt against the unit body
w The seal must have a firm fit at the upper corner on the
handle side. To check, darken the room, place a torch inside
the appliance at the top and close the door. If light shines
through, check the assembly.
5 Connecting the appliance
NOTICE
Risk of damage to the electronic control system!
u Do not use stand-alone inverters (conversion of d.c. to a.c./
three-phase) or energy saving plugs.
WARNING
Fire and overheating hazard!
u Do not use extension cables or multiple socket outlets.
The type of current (alternating current) and voltage at the
installation site have to conform with the data on the type plate
(see Appliance at a glance).
Connect the appliance only with a properly installed
socket outlet with earthing contact. The socket outlet
must be fused with 10 A or higher.
It must be easily accessible so that the appliance can
be quickly disconnected from the supply in an emer-
gency. It must be outside the area of the rear of the
appliance.
u Check the electrical connection.
u Plug in the power plug.
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kd8178afuu/a02Kd8178afa01

Table des Matières