13. Do not drag or push the unit in an installed state.
Do not move the unit using the wheels on the floor. (Always place a mat or similar object underneath.)
The floor may be damaged.
14. Do not stand on the leg/foot massage section.
The end portion of the leg/foot massage section may rotate, or the main unit may tip, causing accident or injury.
Also, the bottom of the leg/foot massage section may make contact with and scratch the floor.
15. Do not insert your feet between the sole section and calf section of the leg/foot massage section and attempt to
stand up.
Failure to observe this precaution may result in accident or injury in a fall.
OPERATING PRECAUTIONS
CAUTION: To avoid damaging the chair, follow these precautions:
1. Do not sit on or drop the controller. Do not pull the controller cord or the power cord. Be careful not to catch the
cord of the controller between the armrest and the chair back.
2. Do not treat the chair roughly, such as turning the chair on its side, turning the chair over or standing on it.
3. Do not treat the covering roughly.
•
Keep sharp or pointed objects away from the covering of the chair. Be careful not to drop lit ashes, lit cigarettes
or matches on the chair.
•
Exposure to direct sunlight can cause fading or a change in color of the covering.
4. If the massager functions abnormally, immediately turn off the power and have the massager checked by an
authorized service center.
5. Do not repeatedly operate any switch at short intervals. Such action may cause the switch to malfunction.
6. Some noise may be heard coming from the massager while in use. This is due to the structure of the massager
and is normal.
7. When excessive pressure is applied to the massage heads, they may stop moving for safety. When moving the
heads up from the lowered position, one's body weight may stop the heads' movement. In such a case, slightly
raise your body and allow the massage heads to move up.
8. After each massage, slide the power switch, which is located on the back side of the chair, to the "off" position
and turn its lock switch to the "lock" position. Remove the key and power plug.
9. Do not sit on the chair with wet body or hair.
10. The unit must not be used in "wet rooms" (sauna, swimming pool) or outdoors.
11. Do not attempt to open or disassemble any part of the unit. Only use an authorized Panasonic servicer to fix
your unit.
3
3-4
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with
all local codes and ordinances.
DANGER
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified
electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided
with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug illustrated in Figure A.
Make sure that the product is connected to an outlet having the same configuration as the plug.
No adapter should be used with this product.
GROUNDING PIN
SPECIFICATIONS
Power Supply:
AC 120 V 60 Hz
Rated Current:
1.2 A
Upper Body Massage
Massage area (Up-Down):
Approx. 25.6 in. (65 cm) [The massage heads move a total of approx. 23.6 in. (60 cm)]
Massage area (Left-Right):
Distance between massage heads during operation
Neck, Shoulder, Back, Lower back: Approx. 1.6 in. – 5.9 in. (4 cm – 15 cm)
Massage area (Forward-Back):
Projected amount of massage head (Intensity adjustable)
Approx. 2.3 in. (6 cm)
Massage speed:
Soft shiatsu: Approx. 285 cycles/minute – 400 cycles/minute (single side)
Knead:
Approx. 14 cycles/minute – 25 cycles/minute
Tap:
Approx. 375 cycles/minute – 495 cycles/minute (single side)
Vertical travel:
Vertical travel (Long): Approx. 25.6 in. (65 cm) up-down auto return
Massage width:
Same as massage area (left-right)
Air massage
Air Pressure (Calf):
3: Approx. 32 kPa
2: Approx. 28 kPa
1: Approx. 20 kPa
Automatic shut-off:
Automatically turns off after a maximum of 15 minutes
Dimensions (H × W × D):
Approx. 33.5 in. × 27.5 in. × 42.5 in. (85 cm × 70 cm × 108 cm)
Weight of Unit:
Approx. 103.9 lbs (47 kg)
Dimensions of box (H × W × D):
Approx. 37 in. × 30.7 in. × 48 in. (94 cm × 78 cm × 123 cm)
Weight in box:
Approx. 130 lbs (59 kg)
•
For those who weighing 220 lbs (100 kg) or more, the product operations may make more noise and the fabric cover may wear
faster.
•
This product is designed for users of between 61 to 72.8 in. (155 to 185 cm) in height.
Users who are taller than approximately 72.8 in. (185 cm) or shorter than approximately 61 in. (155 cm) may not be able to use
the upper body massage and leg/foot massage simultaneously.
Figure A
GROUNDED
OUTLET
GROUNDED
OUTLET BOX
4
2010/01/20
13:28:49