TERMINAL BOARd CONNECTIONS
1-2
Control unit power supply 230 Vac
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
3-4
230 Vac output for the toroidal transformer
5-6
Control unit power supply earth wires
Battery input/output (- and + respectively)
7-8
9-10 Courtesy light output (motor 1 and 2: 24Vdc 5 W)
11
Common for all inputs and outputs
12
LAMP 24Vdc 25W output for warning lights, intermittent
activation (50%), 2,5W continuous activation
13
Controlled output, powering external loads 30 Vdc
14
Output powering external loads 30 Vdc
15-16 Common for all inputs and outputs
17-18 Common for all inputs and outputs
FTCI (NC contact) Safety and control devices in input
19
(photocells invert the travel direction when an obstruction
is detected). Opening this contact will provoke a travel
direction inversion during closure due to the cutting in of
the safety device.
20
TB (NC contact) Stop button input (The opening of this
contact interrupts the cycle until a new movement command
is given)
Td (NO contact) sequential command button input
21
EMRG (NO contact) emergency manoeuvre input 1
22
23
EMRG2 (NO contact) emergency manoeuvre input 2
24
Common for the emergency buttons
25
Outer conductor for radio receiver antenna
26
Inner conductor for radio receiver antenna (if an external
antenna is fitted use a coaxial type cable RG58 with an
impedance of 50Ω).
Note
The total of the 2 external device outputs must not exceed 5W.
(1)
3
21
26
25
24
23
22
B1
R1
J2
L6
L7
L5
P1
Collegamento encoder a 4 fili
Connecting 4-wire encoder
Branchement encoder à 4 fils
Anschluss der Encoder mit 4 Drähten
Conexionado encoder con 4 conductores
B
Signal buzzer "via radio" mode
CSER Serial connection (only for diagnostics)
d
Six-segment LED display
Drawing number :
DC0391
dS
Selection dip-switch
F
Fuse 3,5A (24V circuit protection during battery operation)
310/GLB424SWS
Product Code :
F2
Fuse 0A (motor power protection during battery operation)
Draft :
P.J.Heath
Date :
F3
Fuse 8A (motor power protection)
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
F4
Fuse 3,5A (24V circuit protection)
(1)
20
19
18
17
16
15
14
13
MM
J3
ON
D1
1 2 3 4 5
YELLOW
GREY
GREEN
BLUE
Description :
Elettronica per basculante
(con 6 display a led - selezione a dipswitch )
08-02-2005
ALL UNUSEd NC CONTACTS MUST BE BRIdGEd and conse-
quently the security device test must also be deactivated (TFTC
– dIP 5). If you want to activate the FTCI test both the transmis-
sion and receiver parts of the photocell must be connected to the
binding post marked "CTRL 30 Vdc". If the test is active there
will be a 1 second delay between the command transmission and
movement of the door.
Switch on the power and make sure that the indicator LEDS are in
the following condition:
(1)
- L Power on
- L2 Wrong battery connection
- L3 Battery charging
- L4 Indicates transmitter code programming
- L5 Indicates active inverting photocells "FTCI"
- L6 Indicates active blocking button "TB"
- L7 Indicates active sequential command (Td/CH)
Note
If this LED is "lit" invert the battery power cables imme-
(2)
diately.
Note
This LED is "lit" when the battery is charging.
(3)
Note
(4)
The LEDS are "lit" when the relative safety device is inac-
tive.
Check that the activation of the safety devices (those which have
not been bridged) switch the corresponding LEDS off. If the green
power on LED "L" doesn't light up check the condition of the
fuses and the power cable connection at the transformer. If one
or more of the safety LEDS do not light up check the contacts
of the relative security devices and check that the unused safety
device contacts have been bridged.
DC0391
10
9
12
11
8
7
BATTERY
IN
L2
L3
P2 L4
P3
DS1
COLORE
CABLE COLOUR
CABLAGGI
CODE
Giallo
Yellow
Grigio
Grey
Verde
Green
Blu
Blue
J
Transformer secondary connection
J2
Jumper enabling remote transmitter memorisation
J3
Second radio channel selection jumper
Collegamenti scheda base
MM
Transmitter code memory module TX
P
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (dEL)
R
Radio frequency module, 433 MHz for S449 transmitters
22
CS 1226
L1
YELLOW
GREY
GREEN
BLUE
J1
COLORATION
KABEL-
DES CÂBLAGES
FARBEN
Jaune
Gelb
Gris
Grau
Vert
Grün
Bleu
Blau
lit
off
(2)
off
(3)
off
lit
(4)
lit
(4)
off
M1
M2
230V
N
230V
L
COLORACIÓN
CABLEADOS
Amarillo
Gris
Verde
Azul

Publicité

Table des Matières
loading

Table des Matières