Scope Of Supply; Installation Instructions - solamagic S2 2500 Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Scope of supply

IR heat radiator with mains lead
Mounting bracket including fastenings (supplied)
Manual

Installation instructions

• Install and operate the radiator only in horizontal position!
• The radiator must only be installed using suitable fastenings (e.g. use M6x60
bolts with steel anchors in a stone or concrete substrate) on firm, load-bearing,
normally combustible, flame-resistant or non-combustible substrate.
• If radiator and socket are not installed on the same surface, it must be ensured
that the field of radiation cannot be directed towards the socket. Failing this, it
must be ensured that the socket cannot heat up to more than 70°C during heater
operation.
• The safety distances given in Appendix 2 must be observed.
• The area in which the heat acts can be estimated from the radiation diagram
(Appendix 3). The diagram shows the sizes of the irradiated areas at various dis-
tances from the radiant heater and in each case the maximum radiation intensity.
• Installation height: at least 1.80 m above the ground
• The radiator must be installed with the hammer groove upwards.
• The hammer groove can be seen opposite to the connecting lead in view of the
housing side.
During mounting
always up
During mounting
always down
21
11/2016