Standard configuration
If two cookerhoods-radiocontrol system are
installed in the same room or in the immediate
vicinity, each system may affect the operation
of the other, due to the fact that they have the
same code. Therefore it will be necessary to
change the code of one of the radio controls.
Warning:
The battery should be replaced eve-
ry yearto guarantee the optimal range of
the transmitter. To replace the exhausted
battery, take the plastic lid off, remove the
battery and replace it with a new one, ob-
serving the correct battery polarities. Used
batteries should be discarded in special
collection bins.
Generating a new transmission code
The radiocontrol is supplied by the manufac-
turer with default codes stored. If you want to
create a new set of codes, proceed as follows:
press and hold the UP, STOP and DOWN but-
tons simultaneously for 2 seconds. Afterthe
LEDS light up, press the UP and DOWN button
swithin 5 seconds. The LEDS will flash 3 times
to indicate that the process is completed.
WARNING: This procedure deletes all pre-
viously stored codes.
Learning the new transmission code
After changing the transmission code on the
radio control, the cooker hood electronic con-
trol unit must be made to set the new code
as follows: press the main Power Off button
on the cookerhood (fig. 8) and then restore
power to the electronic control unit. Within
the next 15 seconds, press the Light button.
This will ensure the control unit is synchroni-
zed with the new code.
MAINTENANCE
An accurate maintenance guarantees good
functioning and long-lasting performance.
A special care must be paid with grease fil-
ters: to remove the grease filter please follow
the instructions given in the 'USES' section ,
according to the model chosen.
Remove the grease filter by pulling its handle.
The carbon filter needs to be removed at first
making it slide into its siege and then making
it turn to be easily removed. (fig.17).
To reinsert the grease filter after the cleaning,
just perform the opposite operation.
To clean the appliance itself tepid water and
neutral detergents are recommended, while
abrasive products must be avoided.
The power-supply cable must be replaced by
authorised qualified staff only.
16