SINEAX TV829 Art.-no. 158 312
Specifications (continued)
Isolation
Working voltage
(basic insulation) to
EN 61010-1
Rated insulation voltage
to EN 50124-1
Protection against
electrical shock
For applications with high working voltages, you should ensure there is sufficient spacing
or isolation from neighboring devices and protection against electrical shocks.
36
36
Up to 2200 V AC/DC across input, output, and
power supply with overvoltage category III
and pollution degree 2
(transient overvoltage: max. 13.5 kV).
Up to 2200 V AC/DC across input, output, and
power supply with overvoltage category III
and pollution degree 2
Safe Isolation according to EN 61140 by reinforced
insulation in accordance with EN 61010-1.
Working voltages with overvoltage category III and
pollution degree 2:
– up to 1100 V across input, output, and power supply
– up to 300 V across output and power supply