EN
3. Hang drain hose elbow over edge of drain sink
(Figure 17).
FIG. 17
4. Pull up on drain lever and turn on switch
(Figure 18).
FIG. 18
5. Vacuum motor will pressurize tank and force water
up into drain sink.
16
Home
Find... Go To..

MACHINE MAINTENANCE

To keep machine in good working condition, simply
follow machine's daily, weekly and monthly
maintenance procedures.
WARNING: Hazardous Voltage. Shock or
electrocution can result. Unplug machine before
servicing.

DAILY MAINTENANCE

(Every 4 Hours of Use)
1. Drain and rinse recovery tank after wet vacuuming.
2. Remove and clean float shut--off screen from
recovery tank (Figure 19).
FIG. 19
3. Clean squeegee blades with a cloth. Replace
blades when they become worn.
4. Check bag for fullness, empty bag at 3/4 full.
5. Wipe machine housing with a nonabrasive,
nonsolvent cleaner.
6. Check cords and cord grips for damage. If worn or
damaged, replace immediately. Coil cord neatly.
ATTENTION: Always have float shut- -off screen in
place before operating. During wet operation, the
shut- -off float protects the vacuum motor from
water. During dry vacuuming, the float screen can
provide limited protection for a faulty filter bag.
7. Inspect vacuum hose regularly for holes, loose cuff
or clogged debris.