Machine Maintenance; Storing Machine - Tennant V-WD-15 Manuel Opérateur

Aspirateur à sec/humide
Masquer les pouces Voir aussi pour V-WD-15:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MACHINE MAINTENANCE

To keep machine in good working condition, simply
follow machine's recommended maintenance
procedures.
WARNING: Unplug Power Cord Before
Servicing Machine.
1. Clean secondary filter weekly. Tap or blow off dust
buildup. DO NOT clean with water or solvent.
Filter is located on the vacuum motor as shown.
Replace filter as needed (Figure 14).
FIG. 14
2. Wash cloth filter bag by hand with a mild detergent
as needed. Let bag dry thoroughly before
replacing. This will restore your bag so you can
maintain good suction performance.
ATTENTION: Clogged filters or vacuum hose will
cause vacuum motor to overheat.
3. Clean ball float screen inside tank after every use.
Lift float screen assembly out of tank (Figure 15).
Be certain to replace screen securely .
FIG. 15
V- WD- 15 / V- WD- 15S (04- 2010)
ATTENTION: Always have ball float screen in place
before vacuuming. During wet vacuuming, the
float screen protects the vacuum motor from water
overflows. During dry vacuuming, the float screen
can provide limited protection to vacuum motor
from larger debris in case filter bag breaks.
4. Once each month, spray ball bearings in front
swivel caster with silicone spray.
5. Clean squeegee blades with a cloth whenever they
start to leave streaks on the floor. Replace
squeegee blades when they become worn.
6. Wipe machine housing with a cloth and mild
detergent.
7. Inspect vacuum hose regularly for holes, loose
cuffs or clogged debris.
8. Inspect power cord for damage, replace if
damaged. Coil cord neatly after each use.
WARNING: Do Not Operate With Damaged
Power Cord. Do Not Modify Plug. Unplug Power
Cord Before Servicing Machines.
If the supply cord is damaged or broken, it must be
replaced by the manufacturer or it's service agent
or a similarly qualified person in order to avoid a
hazard.
9. Monthly, check vacuum motor brushes for wear,
replace brushes when 0.38 in / 10 mm or less in
length.
FOR SAFETY: All repairs must be performed by a
qualified service person.

STORING MACHINE

Before storing machine be certain to empty and rinse
recovery tank of all debris or liquids. Store machine in a
dry area with the squeegee removed. Hinge open
recovery lid to promote air circulation. Do not allow
machine to freeze.
WARNING: Do Not Use Outdoors. Do Not
Expose To Rain. Store Indoors.
OPERATION
EN
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

V-wd-15s90074699008703

Table des Matières