Operation
Filling water
The water reservoir can be removed at any time for fill-
ing or be filled directly at the device.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the
water level indicator.
Do not fill in pure distilled water. Use a maximum of 50%
distilled water mixed with tap water.
Do not use condensation from the clothes dryer for fill-
ing.
Do not use collected rain water for filling.
Do not use cleaning agents or other additives (e.g.
scents) for filling.
Remove the water reservoir for filling
1. Pull the water reservoir vertically upwards.
Illustration C
2. Fill the water tank vertically with tap water or a mix-
ture of tap water and no more than 50% distilled wa-
ter up to the "MAX" mark.
3. Insert the water reservoir and press downwards until
it locks into place.
Filling the water reservoir directly on the device
1. Fill tap water or a mixture of tap water and no more
than 50% distilled water from a vessel into the filling
hole of the water reservoir up to the "MAX" mark.
Illustration D
Switch on the device
Note
If there is no or too little water in the steam boiler, the
water pump starts to run and pumps water from the wa-
ter reservoir into the steam boiler. The filling process
can take several minutes.
Note
The device briefly closes the valve every 60 seconds
causing an audible soft click. Closing prevents the valve
from clogging. This does not affect the steam output.
1. Place the device on a firm surface.
2. Insert the mains plug into a socket.
Illustration E
3. Turn the selector switch from the OFF position to
the steam stages.
Illustration F
The steam gun display lights up green.
The steam stage display lights up white and/or the
VapoHydro stage lights up red.
The green heating indicator light flashes.
4. Wait until the green heating indicator stays on.
Illustration G
5. Press the steam lever.
Illustration H
Steam leaks out.
Regulating the steam volume
The expelled steam volume is regulated using the se-
lector switch for steam volume. The selector switch has
5 steam stages for varying types of soiling.
 Steam stage 1
For light soiling, e.g. dust
For objects and surfaces, e.g. plants, sensitive,
painted or coated surfaces
 Steam stage 2
For light to moderate soiling, e.g. finger marks,
dust, food remnants, raindrops, toothpaste
splashes
14
For objects and surfaces, e.g. closed heaters,
mirrors, windows, plastic/metal surfaces
 Steam stage 3
For moderate to heavy soiling, e.g. light grease
residues, finger marks, fly droppings, food or
toothpaste splashes
For objects and surfaces, e.g. kitchen and bath-
room surfaces, windows, ceramic hobs, wall tiles,
tiled floors, PVC, linoleum
 Steam stage 4
For heavy soiling, e.g. older food encrustations,
detergent residues, superficial lime residue, stub-
born grease residues, dried on water marks,
soap residue
For objects and surfaces, e.g. tiled floors, PVC, li-
noleum, wall tiles, tile grout, sinks, shower trays,
bath tubs, bathroom fittings
 Steam stage 5 - VapoHydro function
For areas with an irregular surface, areas with
nooks and crannies that can be sprayed with wa-
ter, e.g. stubborn encrustations, dirt that has col-
lected in the corners and gaps, soap residue, su-
perficial lime residue
For objects and surfaces, e.g. bathroom fittings,
inner window frames (not wooden frames), bath-
room shelves, cooker hobs, shower cubicles,
drains
1. Set the selector switch for the steam volume to re-
quired steam volume.
2. Press the steam lever.
3. Before starting cleaning, point the steam gun at a
cloth until steam is expelled evenly.
If there is not enough water, the water shortage indicator
lamp flashes red and a signal tone sounds.
Note
The water pump fills the steam boiler at intervals. If the
filling is successful, the red water shortage indicator
lamp goes out.
Note
If there is no or too little water in the steam boiler, the
water pump starts to run and pumps water from the wa-
ter reservoir into the steam boiler. The filling process
can take several minutes.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the
water level indicator.
Do not fill in pure distilled water. Use a maximum of 50%
distilled water mixed with tap water.
Do not use condensation from the clothes dryer for fill-
ing.
Do not use collected rain water for filling.
Do not use cleaning agents or other additives (e.g.
scents) for filling.
1. Fill the water tank with tap water or a mixture of tap
water and no more than 50% distilled water up to the
"MAX" mark.
The device is ready for use.

Switching off the device

1. Turn the power switch to "OFF" position.
Illustration N
The device has been switched off.
2. Press the steam lever until no more steam flows out.
Illustration O
The steam boiler is depressurised.
English