general information on grounding. In making the ground connection, the
installer should make certain that there is a solid and permanent metallic
connection between the ground point, the motor or generator terminal housing
and the motor or generator frame.

WIRING YOUR MOTOR

WARNING! Do not touch electrical connections unless you first ensure that
power has been disconnected. Please refer to: OSHA standard 1910.147
titled: The Control of Hazardous energy (lockout/tag-out).
WARNING! Surface temperatures of motor enclosures may reach
temperatures that can cause discomfort or injury to personnel coming in
contact with hot surfaces. Protection should be provided by the user to
protect against accidental contact with hot surfaces. Failure to observe
this precaution could result in bodily injury.
Connect the motor as shown in the connection diagram on the motor nameplate. Be
sure to identify the proper wiring diagram for the motor you are installing. If you
have difficulty determining the proper wiring diagram for your motor, please contact
Princess Auto for assistance.
If this motor is installed as part of a motor control
drive system, connect and protect the motor
according to the control manufacturer's diagram.
When using AC motors with frequency inverters,
be certain that the motors maximum speed rating
is not exceeded. The wiring, fusing and grounding
must comply with the Canadian Electrical Code
(CE) or International Electrotechnical Commission
(IEC) and local codes.
If improper rotation direction is detrimental to
the load, check the rotation or 'bump' the motor
prior to coupling the load to the motor shaft.
When the motor is coupled to the load and
started, it should start quickly and run
smoothly. If not, stop the motor immediately
and determine the cause. Possible causes are:
8