SAFETY ACCESSORIES OPERATION

PHOTOCELL 1 (COM-PHOT 1))
If DIP 6 is OFF - The gate does not open if there Is an obstacle within the photocells
range of action.
During operation, photocells work both when the gate opens (by starting the opening
movement again after half a second time), and when It closes (by starting the reverse
movement after one second time).
If DIP 6 is ON - If there Is an obstacle within the photocells range of action when the gate
is closed and its opening Is commanded, the gate opens (during Its
opening, photocells do not work).
Photocells work only while the gate Is closing (by starting Its reverse motion after one
second, even if they are still engaged).
STOP BUTTON
The STOP button stops the gate during any operation.
If you push it when the gate is totally open (or partly open, by using the pedestrian
command), this button temporary excludes the automatic closing (if selected by DIP3). It
Is than necessary to operate another command to make the gate close again.
The automatic closing function Is enabled again with the following operating cycle (if
selected by DIP3).
N.B.: This electric board can supply power ONLY TO BLINKERS WITH (Code
ACG7059) BLINKING CIRCUIT, with max. 40W lamps.
PRE-BLINKING FUNCTION:
- With DIP8 on OFF => the motor, the blinker and the buzzer start at the same time.
- With DIP 8 on ON => the blinker and the buzzer start 3 seconds before the motor.
BUZZER (Optional)
Current as supplied for buzzer operation 200 mA 12Vdc.
The buzzer emits an intermittent sound signal during opening and closing cycles.
When safety devices are operated (alarm), the intermittence frequency of this
sound signal Increases.
WARNING LIGHT - GATE OPEN (COM-SIGNAL)
Its function Is to signal when the gate Is open, partly open or not totally closed anyway. It
turns off only when the gate Is totally closed.
This warning signal is not enabled during the programming procedures.
N.B.: If you overuse the push button panels or the lamps, the control board logic
system may be compromised, resulting into a possible operation block.

TECHNICAL DATA

- Temperature range
- Moisture
- Power supply voltage
- Frequency
- Max. power consumption of the card
- Transient power mains drops
- Max. capacity of the warning light - gate open -
- Max. load at blinker output
- Available current for photocells and accessories
- Available current for the radio connector
- All the inputs must be used as clear contacts because the power supply is generated
inside (safe power) the control panel, and it has been laid down in such a way to
guarantee a double or strengthened insulation in relation to the parts with dangerous
power.
- Eventual external circuits connected to the outputs of the control board or of the
expander card must be carried out making sure that a double or strengthened insulation
is used in relation to parts with dangerous power.
- All inputs are run by a programmed integrated circuit which does a self check every
time it starts operating.
BLINKER
0 ÷ 55°C
< 95% without condensation
230V~ ±10% (on request 120V±10%)
50/60 H
60 mA
100mS
3 W (corresponding to 1 3W lamp or
to 5 LEDS with 2,2 kΩ resistance
Inseries)
40W with resistive load
0,4 A ±15% 24Vac
200mA 12Vdc
Pag. 25 di 40
E
N
G
L
I
S
H