After having carried out the various connections and having supplied voltage,
all the LEDS are switched OFF.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various START, RADIO, OPEN
and CLOSE buttons.
The electric lock does not work.
Impact sensor intervenes during the movement
The buzzer emits 2 long tones and the gate does not move
The remote control does not work. Led DL12 lit red

ACCESSORIES -

For the connections and the technical data of the optional equipments follow the relevant handbooks.
FOUNDATION BOX FOR DUKE 24V 110°
INOX
RELEASE WITH DIN CYLINDER
S18
S18 to embed (NO+NO)
code ACG1054
S18 to wall (NO+NO)
code ACG1056
FAULT
code ACG8435
code ACG8437I
code ACG2120
S18 to embed (NO+NC)
code ACG1054S
S18 to wall (NO+NC)
code ACG1056S
On the board there are resettable fuses which intervene in the event of a short circuit, interrupting the
output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and insert them
one at a time in order to more easily identify the cause of the fault.
Check fuses F1, F2.
If the fuse is blown, use only a suitable replacement.
F1 T 2A
TRANSFORMER PROTECTION FUSE (on the outside of the B2D 24V board)
F2 T 8A
MOTOR PROTECTION FUSE
Check trimmers RUN and LOW SP adjustment.
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on => check the status of the clock connected to B.I.O..
Photocells Auto-test failed => check the connections between the control panel and the photocells.
Stop, Edge or Photocell with DIP 4 OFF contact fault => Fix or replace the faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the photocells.
Ensure to have enabled DIP 8 to ON.
Check the cable.
Turn the SENS trimmer clockwise
Safety edge with 8,2 KΩ resistor. Remove the resistor or configure the EDGE input via the RIB GATE app
Lack of radio module in connector J6 or faulty radio module.