ELECTRIC CONNECTIONS
ELECTRONIC BOARD KS V.07 FAST
Obligatory software version 07 FAST or following versions FAST.
BC07050
V.07 FAST
A - CONNECTIONS
J1 => EXP.
Connector for EXPANDER card
J2 => SEC.TRANSF.
Connector for secondary transformer
J3 => L1 - N
Power supply 230 Vac 50/60 Hz (on request 120V/60Hz)
J4 => PRI.TRANSF. Connector for primary transformer
J5 =>
DO NOT TOUCH THE JUMPER !
IF IT IS REMOVED THE OPERATOR DOESN'T MOVE !
J6 => SEC.LOCK
Connector to the manual release safety device
J7 => ENCODER
- NOT APPLICABLE -
J8 => CAPACITOR Connector to the capacitor
J9 => Connector for limit switch connection
LSO
Limit switch contact stopping the motor opening
COM.
Contacts common unit
LSC
Limit switch contact stopping the motor closing
J10 => MOTOR
Connector to the Motor
J11 =>
Blinker (max. 40W )
J12 => AERIAL
Radio Antenna
COM
Contacts common unit
PHOT.1 NC Photocells contact (NC)
J13 => INVERTER - NOT APPLICABLE -
J14 => STOP
Contact of the stop button (NC)
OPEN
Contact of the opening button (NO)
CLOSE
Contact of the closing button (NO)
K BUTT.
Contact of a single impulse (NO)
A*A
24 Vac accessories power supply
SIGNAL
Warning light - gate open 12Vdc
Buzzer - Wiring acoustic warning (12Vdc max 200 mA)
J15 => RADIO
Connector for radio receiver 24Vac
J16 => HEATER
Connector for Heater Card
J17 => INVERTER - NOT APPLICABLE -
R2 => TRIMMER LOW SPEED to adjust the speed of the deceleration, both in opening
and closing
R9 => TRIMMER FOR TORQUE to adjust the force of the operator through the
electronic clutch
Pag. 23 di 40