1.0 general information
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m).
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installations. The natural gas model can be installed in a mobile home that is permanently positioned
on its site and fueled with natural gas. This appliance may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certifi ed kit is used.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must
be installed.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from
the plug.
The protective wrap on plated parts is best removed when the assembly is at room temperature but
this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and effi ciencies
Altitude (FT)
Max. Input (BTU/HR)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
Installer, please fi ll out the following information:
Propane:
WHD48
4.5" Water Column (11mb)
13" Water Column (17mb)
3.5" Water Column (9mb)
standard checklist
WHD48P
NG
0-4,500
28,000
11" Water Column (27mb)
13" Water Column (32mb)
10" Water Column (25mb)