Additional clearances - V94i, V94Xi, V75i, V65i
Check on whether local codes supersede these clearances.
•
Avoid termination locations near a dryer vent.
•
Avoid termination locations near commercial
cooking exhaust.
•
You must install a vent termination at least 12
inches from the ground
Important considerations for locating vent
termination under a soffit (ventilated or unventilated
or eave vent; or to a deck or porch)
•
Do not install vent termination under a soffit vent
such that exhaust can enter the soffit vent
•
Install vent termination such that exhaust and
rising moisture will not collect under
eaves. Discoloration to the exterior of the
building could occur if installed too close.
•
Do not install the vent termination too close
under the soffit where it could present
recirculation of exhaust gases back into the
combustion air intake part of the termination
(0.30 m ) to
an inside
corner
8
36"
12"
V
V
12"
(0.30 m) between
terminals at same
level
INSIDE
CORNER
(1.52 m)
between
terminals at
different levels
V
Value Series Manual
60"
V
V
(1.52 m) vertically
60"
between terminals
V
(0.61 m) to wall or parapet
24"
V
12"
(0.30 m) between
terminals at same
V
level
V