Manufacturer's recommendations:
• Read attentively the manufacturer's instructions.
• Positioning of the lamp and connecting of the power supply require great care. To make sure there is a good
conduction of current, the mechanical support and the electrical connections must be free form dirt and corrosion.
The clamps and brackets must be checked whenever the lighting unit has been transported.
• The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.
• It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather.
• Use only when bulb in place
Technical characteristics:
Follow spot description :
Voltage use :
Voltage use :
Minimum voltage supply :
(Below this charge = possible ignition failure).
Lamp description :
Nominal adsorbed wattage :
Lamp voltage :
Lamp current :
Base :
Luminous flux :
Colour temperature :
Manufacturer's rated life :
User's precautions:
• The lamplife, as given by the manufacturer, is an theoretic lamplife duration as "in laboratory conditions" a cycle
based on 3 hours on / 1 hour off, cycles more brief, reduce the duration of the lamplife.
• Premature wearing of lamp under performing conditions, is mainly due to frequent switching on. Better to leave
the lamp on, through the performance, rather than switching it on repeatedly. ( The lampelife is reduced about
1 hour, each time the lamp is lighten ).
• Use over 1500 hours of the lamp : change the lamp even if it still lights up.
New lamp:
• To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on
for a few hours.
• Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event of a dispute.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W MSD COLD STRIKE FOLLOWSPOTS
ADMISSIBLE LAMP :-
PHILIPS: MSD 1200
(European Standard) 230/245 Volts. 50Hz.
(North American standard) 208 Volts 60Hz.
Thank you.
CS - RANGE
CCS - RANGE
198 Volts
1119 CS & CCS
1419 CS & CCS
Section A - 7
110 Volts 60Hz.
105 Volts
MSD 1200
1200 Watts
100 Volts
13,8 Amps
G 22
92 000 L's
6000 Kelvin
2000 Hours