DESCRIPTION.
A
1200W Cold strike profile.
c Lighting unit's power cable.
Cable H07 RN-F 4G 1,5mm
with a 3 point + E, P17 male plug.
B
Power supply unit (P.S.U.)
Refer to sections A -10 & C - 6.
Before connecting to the mains.
- Check the power conformity; P.S.U. power 1 conform with lamp power : 1200W.
- Check the voltage conformity with the mains: 230V/50Hz or 245/50Hz or 208/60Hz.
Untighten the screw 3 .
Turn the switch 4 to select the appropriate voltage.
Then tighten the screw 3 .
Lighting unit / Power supply connection.
- Connect the lighting unit's A power cable C to the P.S.U. B .
- Place the lamp into position - refer to section A - 9.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lamp house's bonnet when
the lighting unit is on.
- Never connect to a dimmable channel.
- Use only when lamp in place.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W MSD COLD STRIKE FOLLOWSPOTS
CONNECTIONS.
A
c
2
length 3m fitted
Make sure the fan is working correctly
when switching on the unit.
For 208/230/245V version.
B
1
2
1119 CS & CCS
1419 CS & CCS
Section A - 5
230V.
50Hz
208V.
245V.
60Hz
50Hz
3
4