7/ DIAGNOSTIC OF THE FAILURES
1
SECURITIES
2
e
Uno model – Redox regulation
ct
ur
Securities
e
Warning abnormal redox value
d
Reminder : the value of the redox potential is shown in tens of mV (ex : 67 = 670 mV).
u
p
The device has detected an abnormal value of the redox, either too high (> 800 mV),
H
either too low (< 400 mV). If the value becomes normal, the blinking disappears.
p
In any case :
ar
1/ Check that the installation is in compliance with the diagram p.6 or 7 and that the probe
di
is connected on the good jack BNC (§3.6, p.23)
o
2/ Measure manually the redox value with an external disposal to verify the indicated
d
e
value of the device.
1
3/ Test the redox probe by proceeding to its calibration with a standard solution 470 mV
Redox
(see §6.2 p.27).
value
If the redox value is too low (< 400 mV) :
flashing
1/ check the ph value is included between 7.0 and 7.4.
2/ Measure the free chlorine rate.
➢ If the value is week, the display flashing is normal. Proceed to a forced march of
➢ If the value is high, check that the stabilizing agent rate is too high (inferior to 20
3/ check that the salt chlorinator is well enslaved to the device, that it is not stopped and
that its production is settled at most.
If the redox value is too high (> 800 mV) :
1/ Measure the free chlorine rate.
2/ Decrease the power of the salt chlorinator production.
Regulation redox securities
Reminder : the redox potential value is shown in tens of mV (ex : 67 = 670 mV).
This alarm starts if the redox measure is always < 200 mV at the end of 12h of salt
A 5
chlorinator work. This alarm is not stored. In the starting up of the device will disappear.
1/ Check that the installation is in compliance with the diagram p.6 or 7 and that the probe
is connected on the good connector (§ 3.6, p.23).
2/ Measure manually the redox value with an external plan to check the value indicated by
the device.
3/ Test the redox probe by proceeding to the calibration with a standard solution 470 mV
(see §6.2 p.27).
4/ Check that the stabilizing agent rate is not too high (inferior to 20 particle by million
recommended). A chlorine too stabilized is no more oxidizer.
Securities pH influence
If the pH is superior at 8.5, the value is really too high and influence the redox measure.
A 6
The device stops the redox regulation until the pH value comes down below 8.5. Check the
pH securities (see p.30).
JUSTREGUL UNO - JUSTREGUL DUO - PAPI004083-MULTI1 - FR/EN/ES/DE - Rev.01.19
24h of the salt chlorinator with the menu MA (see §4.2 p.23-24).
particle by million recommended). A chlorine too stabilised is not oxidizer.
Causes / Remedies
29