SALT CHLORINATOR SLAVERY
2
Connect the chlorinator salt supply to the controller thanks to the supplied connexion fitting.
1/ Connect the salt chlorinator supply cable to the connexion fitting of the device.
2/ Screw the connexion fitting to insure the waterproofness.
3
REDOX PROBE
In compliance with the following layout diagram, the redox probe must be installed after the filter and
before the pH regulation and the chlorination cell.
1/ Put the saddle horizontally on the pipe. Direct the opening
upward. Mark then drills the pipe.
2/ Install with some Teflon the probe-holder on the saddle.
Remove the plastic protection of the redox probe and then
take-up on probe-holder and screw (watch whatever it is not
in abutment with the pipe).
3/ Connect the cable of the redox probe (BNC jack) on the base
of the controller box.
Note : the probe must be installed vertically on the saddle. A different
assembly will damage the precision of the probe measure (can make
it non efficiency).
Duo model
JUSTREGUL UNO - JUSTREGUL DUO - PAPI004083-MULTI1 - FR/EN/ES/DE - Rev.01.19
3/
2/
1/
NON
21