Model Duo – Redox and pH regulation menu
Code
rE
MA
pH
rE
Ad
pH
CP
Co
rE
SE
pH
Maintenance /Diagnostic of failures :
rE
CA
pH
CA
JUSTREGUL UNO - JUSTREGUL DUO - PAPI004083-MULTI1 - FR/EN/ES/DE - Rev.01.19
Forced march of the salt chlorinator (by default 24 h)
Allows forcing the salt chlorinator supply and then its production for a
while fixed.
During the forced march, the resting time is shown on the screen (in hour).
Start a manual injection of the pH pump
Allows correcting by hand the pH without manipulating the tin or
priming the pH pump by example.
During the forced march, the resting time is shown on the screen (in minutes).
Calibrate the Redox probe
Allows calibrating the redox probe by entering a measured value from
the external plan. (unification of the displays if several measure advices
are presents). If the measure is not right, the calibration is rejected
(display Er ; defective probe or out of order).
In any case, do not replace a calibration
Calibrate the pH probe
Allows calibrating the redox probe by entering a measured value from
the external plan. (unification of the displays if several measure advices
are presents). If the measure is not right, the calibration is rejected
(display Er ; defective probe or out of order.
In any case, do not replace a calibration
Adjust the volume of the pool (by default 35 m
This device has a proportional regulation to the volume of the pool. For
an optimum efficiency, register in the device the code corresponding to
the volume of the pool :
Pool volume
Code
3
0 à 1 m
01
3
1 à 2 m
02
3
2 à 3 m
03
3
3 à 4 m
04
3
4 à 5 m
05
3
5 à 6 m
06
3
6 à 7 m
07
3
7 à 8 m
08
3
8 à 9 m
09
3
9 à 10 m
10
Choose the type of corrective agent (by default : acid).
Allows modifying the pH corrective mode between acid (to make the pH
fall) or basic (to make rise the pH).
Adjust the redox regulation instruction (by default 670 mV).
Allows adjusting the redox regulation instruction (in mV) to maintain in
the pool.
Adjust the pH regulation instruction (by default 7,2)
Allows adjusting the pH value to maintain in the pool.
Calibrate the redox probe : maxi distance +/- 100 mV (see § 6.2, p.27).
Calibrate the pH probe : with the standard solutions ph7 and pH 10 (see § 6.2, p.27).
Function
3
)
Pool volume
Code
3
10 à 15 m
11
3
15 à 20 m
12
3
20 à 25 m
13
3
25 à 30 m
14
3
30 à 35 m
15
3
35 à 40 m
16
3
40 à 45 m
17
3
45 à 50 m
18
3
50 à 55 m
19
3
55 à 60 m
20
Pool volume
C ode
3
60 à 70 m
21
3
70 à 80 m
22
3
80 à 90 m
23
3
90 à 100m
24
3
100 à 110m
25
3
110 à 120 m
26
3
120 à 130 m
27
3
130 à 140 m
28
3
140 à 150 m
29
3
150 à 160 m
30
Setting
From 1 h to 24 h
From 0 to 9,5 min
+/- 100 mV
Compared to the
shown value
+/- 0,5 compared
to the shown
value
3
From 5 to 160 m
Acid mode (pH-)
or basic (pH+)
From 550 to
750 mV
From 6.8 to 7.6
24

Publicité

Table des Matières
loading

Table des Matières