4
ACCESSORY PH REGULATION
In compliance with the following layout diagram, the redox probe must be installed after the filter and
before the pH regulation and the chlorination cell.
✓ Put the saddle horizontally after the one of the redox probe on the pipe. Direct the opening upward.
Mark then drills the pipe.
✓ Put the third saddle after the second one by directing the opening upward. Mark then drills the pipe.
5
PH PROBE AND INJECTION SYSTEM
✓ Connect the suction strainer to the entry of the pH pump with a
part of the supplied pipe. Respect the sense of arrows
representing on the top of the pH pump.
✓ Install with some Teflon the injection connector on the third
saddle and hand screw. Connect the exit of the Ph pump (respect
the sense of arrows) to the injection connector with the rest of the
supplied pipe. The injection connector must be closest to the
expulsion towards the pool.
✓ Install with some Teflon the probe-holder on the second saddle
and hand screw. Remove the rubber protection at the end of the
pH probe and screw (make sure that it is not in abutment with the
waterworks).
✓
Connect the cable of the pH probe (BNC jack) under the controller
box.
Note : the probe must be installed vertically on the saddle. A different assembly will damage the precision of the
probe measure (can make it non efficiency).
1/
JUSTREGUL UNO - JUSTREGUL DUO - PAPI004083-MULTI1 - FR/EN/ES/DE - Rev.01.19
3/
2/
An incorrect positioning of
the injection connector can
entail the deterioration of
the pump.
22