LI 16I-TUR
8
Complies with the European safety regulations
9
Additional model features
9.1
Type of defrosting
9.2
Condensate tray frost protection / Water in device is protected from freezing
9.3
Max. operating overpressure (heat sink)
2
10 Heat output / COP
10.1 Heat output / COP
11 Cooling capacity / coefficient of performance (COP)
11.1 Cooling capacity / coefficient of performance (COP)
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45°C to 60°C.
2. This data indicates the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
the regulation should be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning and operation can be found
in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A2/W35: Heat source temperature 2 °C and heating
water flow temperature 35 °C.
3. The maximum sound power level under full load can increase by up to 5 dB(A).
4. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3 db(A).
5. The heat output and COP is reduced by approx. 5% in lower operation
6. The specified sound pressure level represents the free sound area level. The measured value can vary by up to 16 dB(A), depending on the installation location.
7. Note that additional space is required for pipe connections, operation and maintenance.
8. see CE declaration of conformity
9. The heat circulating pump and the heat pump manager must always be ready for operation.
www.glendimplex.de
with A-7 / W35
with A2 / W35
with A7 / W35
2 3
with A27 / W18
with A27 / W7
with A35 / W18
with A35 / W7
452169.66.06 · FD 0009
9
bar
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
English
8
Reverse cycle
Yes
3.0
EN 14511
10.7 / 3.1
6.0 / 4.2
7.1 / 5.1
EN 14511
8.6 / 3.9
8.0 / 3.0
9.8 / 3.6
7.1 / 2.4
EN-17