Technical Data; Electromagnetic Compatibility (Emc) - Minebea Intec PR 6130/08 Manuel D'installation

Masquer les pouces Voir aussi pour PR 6130/08:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cable Junction Box PR 6130/08
3.2

Technical Data

Protection classes
Installation position
Quantity of load cells
Material of the junction box
Color of the junction box
Net weight
Shipping weight
Service temperature area
Storage temperature range
Cable screw connections
Insulation impedance (in service temperature range at
95% air humidity and 500 V DC)
3.3

Electromagnetic Compatibility (EMC)

Housing
Signal and control
lines
Minebea Intec
No.
Description
10
Installation manual 9499 053 00801
11
Certiicates
All data in compliance EN 61326 industrial section
High frequency electromagnetic ields
(80…3000 MHz)
Electrostatic discharge (ESD)
Fast transients (burst)
Peak voltages (surge) 1.2/50 µs
Conducted disturbances by high fre-
quency coupling (0.15…80 MHz)
per DIN EN 60529
IP65:
Dust-proof and leak-proof against water jets (nozzle)
from any angle.
Cable entry from below
max. 8
Polycarbonate
gray, similar to RAL 7035
0.65 kg
0.85 kg
-30°C…+70°C
-30°C…+80°C
Plastic cable screw connections
Polyamide PA6 V-2
>1000 MΩ
EN 61000-4-3
EN 61000-4-2
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
3 Speciications
10 V/m
6/8 kV
1 kV
1 kV
10 V
EN-8