Breakdown Causes Or Interruption - MARTINS Industries Wheelifter 3473 Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. BREAKDOWN CAUSES OR INTERRUPTION

The arrest of the lift or an irregular functioning of it may be due to a few simple reasons shown
in the following table.
If it proves impossible to identify the cause of the malfunction, please contact our technical
department
.
DETECTED PROBLEM
Non functioning or irregular
functioning Ascent/descent
Batteries cannot be charged
POSSIBLE CAUSE
Uncharged batteries
Exceed maximum loading
Fuses
Engine overheating
Defective battery
Non functioning battery charger
Fuses
Batteries are completely
exhausted
18
INSTRUCTIONS ORIGINALES
WHAT TO DO
Charge the batteries
Remove the loading and test the
functioning of the unit
Check the 20A fuse between the
two batteries and replace it if
necessary
Wait for engine cooling down (to
shorten the time open engine
compartment)
Check batteries voltage (2x12V)
Check all connections between
batteries and control board
• Check the 20A fuse between
the two batteries and replace it
if necessary
• Check the fuse on the power
supply
plug
charging and replace it if
necessary
Replace the batteries
for
battery

Publicité