John Bean B 1200P Manuel D'utilisation page 162

Table des Matières

Publicité

162
Setting Parameters
Setting threshold value for unbalance
Resolution of the unbalance amount readings
suppression in g
Selecting the resolution of unbalance readings
in 0.05 / 0.25 oz or 1 / 5 g, increments.
Selecting the limit (threshold) value for
suppression of minor unbalance readings
Normal* =
0.25 oz (5 g) increments
in grammes, or ounces. The unit (gms or
Fine
=
0.05 oz (1 g) increments
oz) depends on the settings made under
"Measurement limit of the unbalance amount
The selected mode of operation can be
readings".
transferred to the permanent memory.
Grammes:
Suppression of minor unbalance amount
Range 3.50 to 20.0 g
readings
Factory–adjusted to 3.5 g
Off
=
Suppression off
On *
=
Suppression on
Ounces:
The selected mode of operation can be
transferred to the permanent memory.
Range 0.25 to 2.00 oz
Factory–adjusted to 0.25 oz
Setting threshold value for unbalance
The selected mode of operation can be
suppression in oz or gms
transferred to the permanent memory.
Selecting the limit (threshold) value for suppression
of minor unbalance readings in grammes, or
Measurement limit of the unbalance amount
ounces. The unit (oz or gms) depends on the
readings
settings made under "Measurement limit of the
unbalance amount readings".
Selecting unbalance readings in grammes or
Ounces:
ounces, active when the machine is switched on.
Range 0.25 to 2.00 oz
Gramm *
=
Factory–adjusted to 0.25 oz
Readings in grammes
Ounze
=
Readings in ounces
Grammes:
The selected mode of operation can be
Range 5 to 20.0 g
transferred to the permanent memory.
Factory–adjusted to 5 g
The selected mode of operation can be
Number of turns
transferred to the permanent memory.
5 to 25 revolutions possible.
Factory–adjusted to 10.*
Measurement limit of the unbalance amount
readings
The selected mode of operation can be
Selecting unbalance readings in grammes or
transferred to the permanent memory.
ounces, active when the machine is switched on.
Ounze*
=
Note
Reducing the number of measurement revolutions
Gramm
=
will reduce the accuracy of measurement.
The selected mode of operation can be
transferred to the permanent memory.
Starting the mesuring run by closing the
wheel guard
Number of turns
5 to 25 revolutions possible.
Off
=
Start via START key
*
Factory–adjusted to 10.*
On* =
Start via wheel guard
The selected mode of operation can be
The selected mode of operation can be
transferred to the permanent memory.
transferred to the permanent memory.
Note
Reducing the number of measurement revolutions
will reduce the accuracy of measurement.
* = Factory adjusted mode
Readings in ounces
Readings in grammes

Publicité

Table des Matières
loading

Table des Matières