Automatic/Manual Range selection
When the meter is switched on, it is in the auto ranging mode. The device
automatically detects the appropriate measuring range. Manual range selection
is not possible.

Auto power off

If no further measurements are carried out, the device switches off automatically
after 10 minutes.
Non Contact Voltage tester (NCV)
1.
To turn on the NCV function, press the NCV key (5.2) for two seconds. The
NCV symbol appears on the display.
2.
Keep the tip of the measuring device to a power outlet or a cable and press
the NCV key. In the presence of dangerous voltage, (>90 V) a signal tone
sounds and the LED indicator lights up.
Attention!
Even without an alarm, dangerous voltage can be concerned! This depends
on various factors. Therefore, if necessary, check the zero voltage with the
voltmeter.
No other measurements are possible in NCV mode.
AC Current measurement and Frequency measurement (Current)
Alternating current measurements are only carried out via the pliers. DC
measurements are not possible.
Always measure current on one conductor only.
Covering more than one conductor results in measuring differential current (like
identifying leakage current). To avoid measuring errors related to other hot
conductors, please observe maximum phase-to-phase clearance.
25
English