2-1. Specifications
Type of Output
Direct Current, Straight
Direct Current, Straight
Polarity (DCEN)
2-2. Duty Cycle And Overheating
5 Minutes Cutting
Overheating
2-3. Cutting Speed
The following curve represents the best cutting scenario achieved using
Extended Cutting consumables, no extension cord and a Miller Bobcat
welding generator with a Kohler engine. Some reduction in performance will
occur with the use of extension cords (approximately 5% per 25 feet of
extension cord), and using shield cutting consumables (approximately 10%).
SECTION 2 – INSTALLATION
Plasma Gas
Rated Output
50 A @ 110 Volts DC,
50 A @ 110 Volts DC,
Air Or Nitrogen Only
50% Duty Cycle
50% Duty Cycle
5 Minutes Resting
0
Minutes
Rated Cutting
Rated Cutting
Capacity
0.7 in (16 mm)
0.7 in (16 mm)
At 10 IPM
15
OR
Reduce Duty Cycle
Maximum Open-
Maximum Open-
Circuit Voltage DC
350
Duty Cycle is percentage of 10 min-
utes that unit can cut at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before cutting.
Y Exceeding duty cycle can
damage unit and void war-
ranty.
A
duty1 4/95
The cutting speed curve shows the
recommended maximum cutting
speed capabilities of the power
source and torch for mild steel of
various thickness.
Y Exceeding
recommended
cutting speeds will cause
rapid erosion of the tip and
electrode.
Cutting speed is approximately
10 inches per minute at 0.7 in (18
mm) mild steel thickness at max
setting/tip saver mode.
ST-191 605