Clearence Dimensions - Bertazzoni PROF304INMXE Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

/ Clearence dimensions

CLEARENCE DIMENSIONS
Installation adjacent to kitchen cabinets
This range may be installed directly adjacent to
existing countertop high cabinets (36" or 91.5 cm
from the fl oor).
For the best look, the worktop should be level with
the cabinet countertop. This can be accomplished
by raising the unit using the adjustment spindles
on the legs.
ATTENTION: the range CANNOT be installed di-
rectly adjacent to kitchen walls, tall cabinets, tall
appliances, or other vertical surfaces above 36"
(91.4 cm) high. The minimum side clearance in
such cases is 6" (15.2 cm).
Wall cabinets with minimum side clearance must
be installed 18" (45.7 cm) above the countertop
with countertop height between 35 ½" (90.2 cm)
and 37 ¼" (94.6 cm). The maximum depth of wall
cabinets above the range shall be 13" (33.0 cm).
Cabinet
A
30'' (76,2 cm)
B
36'' (91,5 cm) hood with combustible materials
C
13'' (33,0 cm)
D
18'' (45,7 cm)
E
35'' 1/2(90,2 cm) / 37"
F
6' (15,2 cm)
D
F
A
E
If installing toekick, verify that the sum of the cu-
tout areas equal the recommended ventilation (L)
30"
area 40 sq. inches
36"
area 51 ½ sq. inches ( 33107 mm2)
48"
area 73 ½ sq.inches
8
(94,6 cm)
1/4
B
C
( 25840 mm2)
( 47547 mm2)
Metal hood
A
30'' (76,2 cm)
B
25 1/2''(65 cm) and 31 1/2'' (80 cm)
C
13'' (33,0 cm)
D
18'' (45,7 cm)
E
35'' 1/2(90,2 cm) / 37"
F
6' (15,2 cm)
G
12"(30,50 cm)
H
1" 9/16(4 cm)
Shaded area behind range indicates minimum
clearance to combustible surfaces, combustible
materials cannot be located within this area.
12" (305 mm) min. to combustible surface with
Flush Island Trim
For Flush Island installations, counter surface
should have a cantilever edge meeting the back
section of the Flush Island Trim accessory.
(94,6 cm)
1/4
B
G
H