WARNING! Threaded pipe joints and connections should be sealed with the
appropriate sealant or sealant tape to minimize the possibility of leaks.
CAUTION! Do not use additional check valves or foot valves unless they have
a proper pressure relief valve built into them. Note that additional check valves
will reduce rate of flow.
CAUTION! A pressure retaining fill cap can be used to reduce fuel loss through
evaporation, but note that it may reduce the flow rate.
Typical Skid Tank
Installation
Materials:
1-1/4" pipe cut to a
length that will extend to
approximately 3" of the
bottom of the tank when
screwed into the tank
adapter with the tank
adapter screwed into the
tank flange (see SKID
TANK INSTALLATION
diagram).
Threaded pipe joint
sealant appropriate for
application.
Installation Procedure:
1)
Thread the 1-1/4" pipe
into the tank adapter.
Seal threads liquid tight
with appropriate thread
sealant.
2)
Screw the tank adapter into the tank flange; seal threads liquid tight with appropriate
thread sealant.
3)
Mount the pump on the adapter; seal threads liquid tight with appropriate thread sealant.
4)
Fill-Rite recommends installation of our Anti-Siphon Device (see page 7 for detailed
information).
WARNING! Threaded pipe joints and connections should be sealed with the
appropriate sealant or sealant tape to minimize the possibility of leaks.
MAXIMUM LIFT
Gasoline 10' (3 m)
Diesel 12' (3.7 m)