iSi Thermo Xpress Whip PLUS. Mode D'emploi page 28

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
3. The puncturing unit has been damaged.
——— Send the whipper to iSi or a service
center.
The content does not stay cool/warm.
The stainless steel bottle gets hot or cold to the
touch.
1. The insulating chamber has been damaged –
loss of thermal effect.
——— "Release pressure". Send the device to
the iSi service center.
Gas escapes between the bottle and the head
during charging.
1. There is no bottle gasket.
——— "Release pressure". Insert the bottle
gasket with riser tube.
2. The bottle gasket has been damaged.
——— "Release pressure". Replace the bottle
gasket.
3. The head was not screwed on securely
enough.
——— "Release pressure". Screw the head
onto the bottle in accordance with the
instructions for use so that it is straight
and sealed tightly.
4. Bottle has been damaged on the upper edge.
——— "Release pressure". Send the device to
the iSi service center.
The content leaks when the device is charged.
1. The push button has not been screwed onto
the device head securely enough.
——— Screw the push button on to the device
head until it no longer turns .
2. Gaskets in push button damaged.
——— Replace push button.
It is difficult to screw on the charger holder.
1. The charger used is not compatible.
——— Only use original iSi Cream Chargers.
2. There is too much resistance between the
threads of the charger holder and piercing
unit.
——— Regularly oil the charger holder thread
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Thermo xpress whip.plus

Table des Matières