5-9. Placing Jumper Links

208 VOLTS
L1
L2
1
230 VOLTS
L
L
1
2
!
Disconnect and lockout/tagout in-
put power before installing or mov-
ing jumper links.
Jumper links allow operation on different in-
put voltages and are factory set for the high-
est input voltage.
Check input voltage available at site.
230 VOLTS
L3
L
3
Open rear panel access door to check
jumper links.
1
Input Voltage Label − Only One Is On
Unit
Look at jumper links and compare link posi-
tion with unit label.
2
Input Voltage Jumper Links
2
L1
L2
L3
460 VOLTS
L
L
L
1
2
3
460 VOLTS
L1
L2
L3
S-011 406-B
575 VOLTS
L
L
L
1
2
3
S-094 120-B
Move links to match input voltage. For ex-
ample, use 230 volts position when 230
volts input power is available.
.
Tighten jumper link nuts to 25 in lb +/- 5
in lb (2.8 NVm +/-.6 NVm)
Close and secure door or go on to 5-9B.