Foreman Ductable Oil Indirect-Fired Heater

Belt Replacement

1. Carefully remove belt from pulley.
2. Check the fan and motor pulley grooves for dirt,
clean the pulleys if needed.
3. Install new belt. Ensure belt is installed as shown
below. See directional arrow on belt.

Fan and Motor Pulleys

1. Remove belt from pulleys. See Belt Replacement.
2. Loosen allen screw on fan and motor pulleys.
3. Remove pulley and key from fan shaft and motor.
4. When installing new pulley, use a straight edge,
check motor and fan pulley alignment. Contact must
be made at edges of both pulleys.
Owner's Manual • Foreman

Fan Motor

1. Loosen electrical supply access panel screws on
motor
2. Remove access panel and gasket
3. Disconnect power supply wire.