Fein WSG8-115 Série Mode D'emploi page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OBJ_BUCH-0000000224-002.book Page 13 Tuesday, February 23, 2016 10:09 AM
Extension cable.
If the use of an extension cord
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool. Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
Recommended dimensions of extension
cables at an operating voltage of 120 V – sin-
gle-phase a. c., with only one power tool
WSG8 (**), WSG11 (**), WSG12 (**),
WSG17 (**) connected:
Intended use of the power tool:
Hand-guided angle grinder for dry grinding
and cutting of metal and stone in weather-
protected environments with the application
tools and accessories recommended by FEIN.
Operation of the power tool off power generators.
This power tool is also suitable for use
with AC generators with sufficient power
output that correspond to the Standard
ISO 8528, design type G2. This Standard is
particularly not complied with when the so-
called distortion factor exceeds 10 %. When
in doubt, please refer to the generator
instruction/specification guide.
WSG12 (**), WSG17 (**):
Max. cable length, ft
Max. cable length, m
≤ 100
100
200
–200
–300
Min. conductor size
Min. conductorcross-
A.W.G.
section, mm
14
12
10
WSG8 (**), WSG11 (**):
Max. cable length, ft
Max. cable length, m
≤ 100
100
200
–200
–300
Min. conductor size
Min. conductorcross-
A.W.G.
section, mm
16
14
12
Operating the power tool off
WARNING
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
en
13
≤ 30
30
60
– 60
–100
2
2.5
4.0
6.0
≤ 30
30
60
– 60
–100
2
1.5
2.5
4.0

Publicité

Table des Matières
loading

Table des Matières